Hijack v487 is now released.

This version automatically fixes the temperature sensor if it was stuck in one-shot mode -- five out of six(!) of my own players had this problem, a legacy from years ago before we fixed the interrupt masking around sensor accesses.

The fix is totally automatic, and permanent, on boot.

This means that temperature data on affected units will now be updated every 5 seconds, instead of every 5 minutes. And the 5-minute hack is now removed from Hijack altogether.

This will *not* fix a totally dead sensor. That still requires hardware intervention, as described elsewhere in this forum.

Cheers


Edited by mlord (15/02/2008 01:24)