Here is some info describing the Kenwood protocol.
******************************************************************************
TECHNICAL INFO
******************************************************************************
Code length: 32 bits
Carrier: 39.2kHz

The code is only transmitted once, and after that a stop code is transmitted.



+--------------------------------+
Header: | |
+ +----------------+..
16T 8T
8.8ms 4.4ms

+--+
1 is coded: | |
..+ +------+..
T 3T

+--+
0 is coded: | |
..+ +--+..
T T

+--------------------------------+ +--+
Stop code: | | | |
+ +--------+ +
16T 4T T
8.8ms 2.2ms

T = 550us

Space between transmissions: 95000us between the start of the codes.

To use the code (not with the remote package):
GROUP * 10000h + (Code * 100h) + (Code XOR FFh)


Brian