The empeg's amp remote is linked to the display power. When the display is on (ie, standby LED off) the amps are powered.

This is fine for power up & power down: on powerup, the display is not turned on for a few seconds which means the analogue outputs are stable. On power down the display is turned off a few seconds before it shuts main power down, keeping the outputs stable until the amp has died.

Hugo