Originally Posted By: sein

My Multimeter has a 'MIN' mode that I was using which holds the minimum value it sees. I was using that, but I still think it doesn't have fast enough reactions to give a reading that I have confidence in. Every time I press the button I would see its little fast reacting LCD bar move but it would only give me a readout around one in ten presses.

Mmm.. something's wrong there. They must have a capacitor or something (internal to the stalk) that's in series with the output or something. That has to be fixed before it will work with the empeg tuner inputs.


Quote:
The Vol+ and Vol- readings are dead on though, every time they give exactly that reading (no need for the minimum function, just hold the button).


Okay, so those two should be usable, if they're within range. My real stalk reads 23.6K and 17.5K for those two, give or take a few percent.