Quote:
I am finding that 2 lots of samples are being taken for J10 and K10

Any ideas what's going on? I was thinking that the sample period may not be long enough so it starts the process again.


Yes, you are correct. It's is taking longer than 2.56 seconds to send K10 on your wallbox. The worst case pulse time on your 50Hz wallbox is about 114.5 msec. My 60Hz wallbox worst case pulse time is 76.5ms. I would have expected the worst case pulse time of a 50Hz box to be 60/50*76.5ms = 92ms. Your box seems slow, you might want to try another wallbox, or try a slighly higer voltage, say 28-30V. Do the lights look nice and bright? Can you measure the AC voltage at the imput terminals when the motor is running?

-Techtom