Ok. In Australia breakers are always (to my knowledge) broken up into lights vs power points/fixed electrical. Definitely "geographical" after that though of course. Usually light circuits aren't RCD protected so are on separate circuits.

Same here. Power sockets are also on 20A breakers and use 2.5mm˛ wire, while lights are on 16A breakers and use 1.5mm˛ wire. Up to 8 power sockets may be implemented on one circuit that's protected with a 20A breaker. If there are more, you need to create an additional circuit.
Also, ALL circuits are RCD protected. There are 2 sorts: 30mA for the "wet" rooms, like bathrooms, kitchens and the room with the washing machine (basically, anywhere where there's water), and 300mA for the "dry" rooms.