Quote:
..
ide_data_test: wrote 0x0000 read 0x0000
ide_data_test: wrote 0xffff read 0xffff
ide_data_test: wrote 0xaaaa read 0xaaaa
ide_data_test: wrote 0x5555 read 0x5555
hda: probing with STATUS(0x50) instead of ALTSTATUS(0xff)
hda: IBM-DARA-212000, ATA DISK drive
i..
ide0 at 0x000-0x007,0x038 on irq 6
hda: IBM-DARA-212000, 11513MB w/418kB Cache, CHS=23392/16/63
..
Partition check:
hda: hda1 < hda5 hda6 > hda2 hda3 hda4
..
hda: status timeout: status=0xff
hda: drive not ready for command
ide0: reset: failed
hda: lost interrupt
hda: lost interrupt


The CS1- line is bad (stuck high) between the SA1100 and the drive, or the associated pull-up resistor on that line is bad. CS1- is pin 38 on the 44-pin IDE header.

EDIT: or possibly CS0- (pin 37) is stuck low.


Edited by mlord (26/04/2007 10:56)